PartsTable
Technical Data Sheet
126C459 ✓ Verified by PartsTable
· WIRE CABLE
WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

CABLE ASSEMBLY,POWER,ELECTRICAL. Key specifications include material: PLASTIC FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS, conductor_form: STRANDED ALL CONDUCTORS, overall_length: 20.250 INCHES IN, voltage_rating: 600.0 DC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS, style_designator: INTERNAL AND EXTERNAL ANGLE CONNECTOR, termination_type: TERMINAL LUG FIRST END ALL CONDUCTORS. This product is currently in active production with full OEM support.

This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6150-00-549-6752, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
126C459
NSN: 6150-00-549-6752
FSC: 6150
CAGE: 24446 — GENERAL ELECTRIC COMPANY (USA)
SPECIFICATIONS
materialPLASTIC FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
conductor_formSTRANDED ALL CONDUCTORS
overall_length20.250 INCHES IN
voltage_rating600.0 DC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
style_designatorINTERNAL AND EXTERNAL ANGLE CONNECTOR
termination_typeTERMINAL LUG FIRST END ALL CONDUCTORS
conductor_quantity3
round_conductor_size0000 AWG ALL CONDUCTORS
strand_awg_size_per_conductor30 ALL CONDUCTORS
strand_quantity_per_conductor2104 ALL CONDUCTORS
conductor_arrangement_and_quantity3 SINGLES
terminal_commercial_and_government_entity_code81482 SECOND END ALL CONDUCTORS
NSN6150-00-549-6752
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: 126C459 · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE: 81482 FIRST END ALL CONDUCTORS
MATERIAL: COPPER ALLOY CORE CONDUCTOR ALL CONDUCTORS
CONDUCTOR QUANTITY: 3
CONDUCTOR ARRANGEMENT AND QUANTITY: 3 SINGLES
STYLE DESIGNATOR: INTERNAL AND EXTERNAL ANGLE CONNECTOR
STRAND QUANTITY PER CONDUCTOR: 2104 ALL CONDUCTORS
TERMINATION TYPE: CONNECTOR PLUG SECOND END ALL CONDUCTORS
TYPICAL APPLICATIONS
  • Server Internal Cabling
  • Data Center Cable Infrastructure
  • SAS/SATA Drive Connectivity
TECHNICAL CHARACTERISTICS (FLIS)
OVERALL LENGTH20.250 INCHES IN
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE81482 FIRST END ALL CONDUCTORS
MATERIALCOPPER ALLOY CORE CONDUCTOR ALL CONDUCTORS
CONDUCTOR QUANTITY3
CONDUCTOR ARRANGEMENT AND QUANTITY3 SINGLES
STYLE DESIGNATORINTERNAL AND EXTERNAL ANGLE CONNECTOR
STRAND QUANTITY PER CONDUCTOR2104 ALL CONDUCTORS
TERMINATION TYPECONNECTOR PLUG SECOND END ALL CONDUCTORS
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE81482 SECOND END ALL CONDUCTORS
MATERIALPLASTIC FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
VERIFIED SUBSTITUTES & CROSS-REFERENCES 14
11-1-28Interchangeable
interchangeable cross-reference
interchangeable
128-C-69Interchangeable
interchangeable cross-reference
interchangeable
1793-128Interchangeable
interchangeable cross-reference
interchangeable
10163247Interchangeable
interchangeable cross-reference
interchangeable
676Interchangeable
interchangeable cross-reference
interchangeable
645Interchangeable
interchangeable cross-reference
interchangeable
LIFECYCLE
StatusACTIVE
AvailabilityOEM and secondary market
RoHS CompliantEAR99Not HAZMAT
Ready to buy 126C459?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 126C459?
126C459 is a CABLE ASSEMBLY,POWER,ELECTRICAL.
What parts can replace 126C459?
There are 14 known substitutes for 126C459: 11-1-28, 128-C-69, 1793-128 and 11 more. Substitute compatibility should be verified for your specific system.
What is the NSN for 126C459?
126C459 is cataloged in the Federal Logistics Information System (FLIS) under NSN 6150-00-549-6752. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 126C459