12-16382-01: FILTER,RADIO FREQUENCY INTERFERE.
FILTER,RADIO FREQUENCY INTERFERE. Key specifications include body_material: METAL, inclosure_type: ENCASED, special_features: TWO FILTERED FUNCTIONS, maximum_temp_rise: 25.0 CELSIUS DEGC, operating_temp_range: -55.0 TO 85.0 CELSIUS DEGC, load_impedance_per_function: 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION. This part is cataloged in the U.S.
Government catalog under NSN 5915-01-255-8695, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| body_material | METAL |
| inclosure_type | ENCASED |
| special_features | TWO FILTERED FUNCTIONS |
| maximum_temp_rise | 25.0 CELSIUS DEGC |
| operating_temp_range | -55.0 TO 85.0 CELSIUS DEGC |
| load_impedance_per_function | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| maximum_voltage_drop_per_function | 1.15 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| vibration_resistance_range_in_hertz | +10.0 TO 500.0 |
| source_impedance_rating_per_function | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| principal_circuitry_type_per_function | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION |
| operating_current_rating_per_function_in_amps | 10.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| operating_voltage_rating_and_type_per_function | 115.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| NSN | 5915-01-255-8695 |
| INCLOSURE TYPE | ENCASED |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 500.0 |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| BODY MATERIAL | METAL |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |