11447849: INSULATION SLEEVING,ELECTRICAL,S.
INSULATION SLEEVING,ELECTRICAL,S. Key specifications include material: PLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED, flexibility: FLEXIBLE, temp_rating: -55.0 CELSIUS DEGC, environmental_protection: CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT, main_body_overall_length: 4.600 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN, main_body_wall_thickness: 0.100 INCHES NOMINAL AS SUPPLIED IN. This part is cataloged in the U.S.
Government catalog under NSN 5970-01-082-5420, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| material | PLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED |
| flexibility | FLEXIBLE |
| temp_rating | -55.0 CELSIUS DEGC |
| environmental_protection | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
| main_body_overall_length | 4.600 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| main_body_wall_thickness | 0.100 INCHES NOMINAL AS SUPPLIED IN |
| minimum_tensile_strength | 1500 POUNDS PER SQUARE INCH LBS |
| main_body_inside_diameter | 0.600 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| first_branch_wall_thickness | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| first_branch_inside_diameter | 0.350 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| second_branch_wall_thickness | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| material_document_and_classification | RT-1304,RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED |
| NSN | 5970-01-082-5420 |
| TEMP RATING | -55.0 CELSIUS DEGC |
| FLEXIBILITY | FLEXIBLE |
| MATERIAL DOCUMENT AND CLASSIFICATION | RT-1304,RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED |
| DISTANCE FROM CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.300 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| SECOND BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| MAIN BODY INSIDE DIAMETER | 1.200 INCHES MINIMUM AS SUPPLIED IN |
| MAIN BODY INSIDE DIAMETER | 0.600 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| MAIN BODY OVERALL LENGTH | 4.600 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH/ IN |
| FIRST BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |