110798-1: WAVEGUIDE ASSEMBLY,FILTER.
The WAVEGUIDE ASSEMBLY,FILTER is a the manufacturer industrial component. Key specifications include material: ALUMINUM SINGLE TUBING SEGMENT, flange_style: CONTACT, DOUBLE RIDGE TYPE ALL FLANGES, style_designator: STRAIGHT TYPE, waveguide_length: 6.350 INCHES NOMINAL IN, surface_treatment: PAINT SECOND TUBING SEGMENT OUTSIDE SURFACES, specified_frequency: 3.625 GIGAHERTZ MINIMUM AND 4.2 GIGAHERTZ MAXIMUM. This part is cataloged in the U.S.
Government catalog under NSN 5985-01-475-8711, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| material | ALUMINUM SINGLE TUBING SEGMENT |
| flange_style | CONTACT, DOUBLE RIDGE TYPE ALL FLANGES |
| flange_quantity | 2 |
| style_designator | STRAIGHT TYPE |
| waveguide_length | 6.350 INCHES NOMINAL IN |
| surface_treatment | PAINT SECOND TUBING SEGMENT OUTSIDE SURFACES |
| specified_frequency | 3.625 GIGAHERTZ MINIMUM AND 4.2 GIGAHERTZ MAXIMUM |
| insertion_loss_in_decibels | 0.035 |
| cross-sectional_shape_style | INTERNAL, RECTANGULAR SINGLE RIDGED EXTERNAL, RECTANGULAR |
| voltage_standing_wave_ratio | 1.10 |
| NSN | 5985-01-475-8711 |
| FLANGE QUANTITY | 2 |
| VOLTAGE STANDING WAVE RATIO | 1.10 |
| STYLE DESIGNATOR | STRAIGHT TYPE |
| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR SINGLE RIDGED EXTERNAL, RECTANGULAR |
| WAVEGUIDE LENGTH | 6.350 INCHES NOMINAL IN |
| SPECIFIED FREQUENCY | 3.625 GIGAHERTZ MINIMUM AND 4.2 GIGAHERTZ MAXIMUM |
| INSERTION LOSS IN DECIBELS | 0.035 |
| SPECIAL FEATURES | MANUFACTURER NOMENCLATURE TRANSMIT REJECT FILTER C-BAND; FREQUENCY RANGE 3.625 - 4.200 GHZ; PRESSURIZATION SEALED TO 5 PSI; TEMPERATURE RANGE -40 TO +80 DEGREES C; INTERIOR AND FLANGE FACE FINISH ARE CADMIUM PLATED; EXTERIOR WHITE PAINT GHz |
| SURFACE TREATMENT | CADMIUM FIRST FLANGE ALL SURFACES |
| SURFACE TREATMENT | PAINT SECOND TUBING SEGMENT OUTSIDE SURFACES |
No substitute or cross-reference records for this part.