PartsTable
Technical Data Sheet
11-00729-4 ✓ Verified by PartsTable
· MRO · MRO_GENERAL
WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

The 11-00729-4 is a the manufacturer industrial component. Key specifications include color: YELLOW CORE CONDUCTOR SINGLE CONDUCTOR, material: PLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR, temp_rating: 200.0 CELSIUS DEGC, conductor_form: STRANDED SINGLE CONDUCTOR, voltage_rating: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR, surface_treatment: SILVER CORE CONDUCTOR SINGLE CONDUCTOR. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-00-608-7783, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL 11-00729-4
NSN: 6145-00-608-7783
FSC: 6145
CAGE: 05973 — CHAMPLAIN CABLE CORP SUB OF HUBER AND SUHNER INC (USA)
SPECIFICATIONS
colorYELLOW CORE CONDUCTOR SINGLE CONDUCTOR
materialPLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
temp_rating200.0 CELSIUS DEGC
conductor_formSTRANDED SINGLE CONDUCTOR
voltage_rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
surface_treatmentSILVER CORE CONDUCTOR SINGLE CONDUCTOR
round_conductor_size16 AWG SINGLE CONDUCTOR
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor29 SINGLE CONDUCTOR
strand_quantity_per_conductor19 SINGLE CONDUCTOR
cross_section_outside_diameter0.075 INCHES NOMINAL IN
NSN6145-00-608-7783
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: 11-00729-4 · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
COLOR: YELLOW CORE CONDUCTOR SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR: 19 SINGLE CONDUCTOR
SURFACE TREATMENT: SILVER CORE CONDUCTOR SINGLE CONDUCTOR
TEST DATA DOCUMENT: 81349-MILW22759 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
STRAND AWG SIZE PER CONDUCTOR: 29 SINGLE CONDUCTOR
CONDUCTOR FORM: STRANDED SINGLE CONDUCTOR
MATERIAL: COPPER CORE CONDUCTOR SINGLE CONDUCTOR
VOLTAGE RATING: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
TECHNICAL CHARACTERISTICS (FLIS)
COLORYELLOW CORE CONDUCTOR SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR19 SINGLE CONDUCTOR
SURFACE TREATMENTSILVER CORE CONDUCTOR SINGLE CONDUCTOR
TEST DATA DOCUMENT81349-MILW22759 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
STRAND AWG SIZE PER CONDUCTOR29 SINGLE CONDUCTOR
CONDUCTOR FORMSTRANDED SINGLE CONDUCTOR
MATERIALCOPPER CORE CONDUCTOR SINGLE CONDUCTOR
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
MATERIALPLASTIC POLYTETRAFLUOROETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
CROSS SECTION OUTSIDE DIAMETER0.075 INCHES NOMINAL IN
VERIFIED SUBSTITUTES & CROSS-REFERENCES 24
M22759/11-16-9Upgraded Successor
successor cross-reference
successor
417056-19Upgraded Successor
successor cross-reference
successor
SAE-AS22759/11Upgraded Successor
successor cross-reference
successor
MIL-W-22759/11Upgraded Successor
successor cross-reference
successor
7735240P18984Upgraded Successor
successor cross-reference
successor
AS22759/11Upgraded Successor
successor cross-reference
successor
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy 11-00729-4?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 11-00729-4?
11-00729-4 is a 11-00729-4. It is classified as a MRO (MRO_GENERAL).
What parts can replace 11-00729-4?
There are 24 known substitutes for 11-00729-4: M22759/11-16-9, 417056-19, SAE-AS22759/11 and 21 more. Substitute compatibility should be verified for your specific system.
Is 11-00729-4 still available?
11-00729-4 is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 11-00729-4