106441-06: WAVEGUIDE ASSEMBLY.
The WAVEGUIDE ASSEMBLY is a the manufacturer industrial component. Key specifications include material: ALUMINUM ALLOY ALL TUBING SEGMENT, flexibility: FLEXIBLE OR RIGID ALL TUBING SEGMENT, flange_depth: 0.250 INCHES NOMINAL ALL FLANGES IN, flange_style: CONTACT, DOUBLE RIDGE TYPE ALL FLANGES, thread_class: 2B ALL FLANGES ALL CONNECTION FACILITIES, style_designator: DOUBLE BEND TYPE. This part is cataloged in the U.S.
Government catalog under NSN 5985-01-375-9891, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| material | ALUMINUM ALLOY ALL TUBING SEGMENT |
| flexibility | FLEXIBLE OR RIGID ALL TUBING SEGMENT |
| flange_depth | 0.250 INCHES NOMINAL ALL FLANGES IN |
| flange_style | CONTACT, DOUBLE RIDGE TYPE ALL FLANGES |
| thread_class | 2B ALL FLANGES ALL CONNECTION FACILITIES |
| flange_quantity | 2 |
| style_designator | DOUBLE BEND TYPE |
| thread_direction | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES |
| waveguide_height | 3.780 INCHES MINIMUM AND 4.040 INCHES MAXIMUM IN |
| surface_treatment | CHROMATE ALL TUBING SEGMENT ALL SURFACES |
| flange_inside_width | 0.795 INCHES MINIMUM AND 0.801 INCHES MAXIMUM ALL FLANGES IN |
| nominal_thread_size | 0.138 INCHES ALL FLANGES ALL CONNECTION FACILITIES IN |
| NSN | 5985-01-375-9891 |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |
| FLANGE INSIDE HEIGHT | 0.425 INCHES MINIMUM AND 0.431 INCHES MAXIMUM ALL FLANGES IN |
| WAVEGUIDE HEIGHT | 3.780 INCHES MINIMUM AND 4.040 INCHES MAXIMUM IN |
| FLANGE QUANTITY | 2 |
| VOLTAGE STANDING WAVE RATIO | 1.35 |
| STYLE DESIGNATOR | DOUBLE BEND TYPE |
| FLEXIBILITY | FLEXIBLE OR RIGID ALL TUBING SEGMENT |
| WAVEGUIDE INSIDE WIDTH | 0.691 INCHES NOMINAL IN |
| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR |
| FLANGE OUTSIDE HEIGHT | 1.360 INCHES MINIMUM AND 1.390 INCHES MAXIMUM ALL FLANGES IN |