The TRANSFORMER,POWER is a the manufacturer industrial component. Key specifications include body_width: 2.120 INCHES NOMINAL IN, body_height: 1.560 INCHES MAXIMUM IN, inclosure_type: FULLY INCLOSED, overall_length: 3.320 INCHES NOMINAL IN, mounting_method: THREADED HOLE(S) SINGLE GROUP, frequency_rating: 360.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT. This product is currently in active production with full OEM support.
This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5950-01-043-3165, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| body_width | 2.120 INCHES NOMINAL IN |
| body_height | 1.560 INCHES MAXIMUM IN |
| inclosure_type | FULLY INCLOSED |
| overall_length | 3.320 INCHES NOMINAL IN |
| mounting_method | THREADED HOLE(S) SINGLE GROUP |
| frequency_rating | 360.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT |
| special_features | 1 PRIMARY,6 SECONDARY WINDINGS; SECONDARY 6 HAS MULTIPLE TAPS PROVIDING VOLTAGES WITH VARYING CURRENTS IN MILLIAMPERES |
| nominal_thread_size | 0.138 INCHES SINGLE GROUP IN |
| reliability_indicator | NOT ESTABLISHED |
| thread_series_designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| winding_shielding_method | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| winding_operating_current | 1.6 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| NSN | 5950-01-043-3165 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| OVERALL LENGTH | 3.320 INCHES NOMINAL IN |
| FREQUENCY RATING | 360.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT |
| SPECIAL FEATURES | 1 PRIMARY,6 SECONDARY WINDINGS; SECONDARY 6 HAS MULTIPLE TAPS PROVIDING VOLTAGES WITH VARYING CURRENTS IN MILLIAMPERES |
| MOUNTING METHOD | THREADED HOLE(S) SINGLE GROUP |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 6 SECONDARY SINGLE COMPONENT |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| WINDING OPERATING VOLTAGE | 10.68 AC VOLTS MINIMUM AND 11.12 AC VOLTS MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| WINDING OPERATING CURRENT | 1.6 AMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |