0661630005: RELAY,ELECTROMAGNETIC.
The RELAY,ELECTROMAGNETIC is a the manufacturer industrial component. Key specifications include duty_type: CONTINUOUS, time_delay: 0.0003 SECONDS MAXIMUM FIXED RELEASE TIME, frequency_in_hertz: 60.0 MINIMUM AND 400.0 MAXIMUM, environmental_protection: HERMETIC, precious_material_and_location: CONTACTS GOLD AND CONTACTS SILVER, main_contact_maximum_voltage_rating_in_volts: 115.0 AC AND 30.0 DC. This part is cataloged in the U.S.
Government catalog under NSN 5945-01-477-5531, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| duty_type | CONTINUOUS |
| time_delay | 0.0003 SECONDS MAXIMUM FIXED RELEASE TIME |
| frequency_in_hertz | 60.0 MINIMUM AND 400.0 MAXIMUM |
| environmental_protection | HERMETIC |
| precious_material_and_location | CONTACTS GOLD AND CONTACTS SILVER |
| main_contact_maximum_voltage_rating_in_volts | 115.0 AC AND 30.0 DC |
| main_contact_load_current_rating_at_maximum_rated_voltage | 0.5 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
| NSN | 5945-01-477-5531 |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 30.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.5 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
| DUTY TYPE | CONTINUOUS |
| FREQUENCY IN HERTZ | 60.0 MINIMUM AND 400.0 MAXIMUM |
| TIME DELAY | 0.0003 SECONDS MAXIMUM FIXED RELEASE TIME |
| TIME DELAY | 0.0004 SECONDS MAXIMUM FIXED OPERATE TIME |
| SPECIAL FEATURES | HERMETICALLY SEALED; TOTAL SUBMERSIBILITY; INSULATION RESISTANCE 1000.0 MEGOHMS MIN. AT 500 VDC; BREAKDOWN VOLTAGE 500.0 VOLTS RMS 60.0 HERTZ BETWEEN ALL MUTUALLY INSULATED POINTS; TEMP. RANGE MINUS 55.0 TO PLUS 71.0 DEG. C; RATED LIFE 100000 OPERATIONS MIN. AT MAX. RATED LOAD; TERMINALS 0.030 IN. DIA. LOCATED ON 0.200 IN. GRID PATTERN; CONFIGURATION 2 FORM C, DOUBLE POLE DOUBLE THROW; CONTACT RESISTANCE 50.0 MILLIOHMS MAX. INITIAL MEASURED AT MAX. RATED LOAD; SENSITIVITY OF 350.0 MILLIWATTS NOMINAL AT PLUS 25.0 DEG. C; NOMINAL POWER 660.0 MILLIWATTS AT PLUS 25.0 DEG. C; 24 VOLT COIL; WEIGHT IS 0.035 OUNCES VDC |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| PRECIOUS MATERIAL AND LOCATION | CONTACTS GOLD AND CONTACTS SILVER |
No substitute or cross-reference records for this part.